Resources What's New Support Download Contact Sales: Arthur-Industrial@outlook.com
Home › Resources › Nelson rules quick reference

Nelson rules quick reference

The eight pattern rules in one table, with typical causes.

Zones: C is 0 to 1σ from the center line, B is 1 to 2σ, A is 2 to 3σ. Rules 1, 5, 6 and 2 (with 8 points) are the original Western Electric rules; Nelson added the rest.

RulePatternUsually means
11 point beyond 3σ (zone A edge)A large, sudden shift or a one-off error
29 points in a row on the same side of the center lineA shift in the process mean
36 points in a row, all increasing or all decreasingA trend: tool wear, temperature drift
414 points in a row alternating up and downTwo alternating sources (two machines, two operators)
52 of 3 points in a row beyond 2σ, same sideAn early sign of a shift
64 of 5 points in a row beyond 1σ, same sideA small shift
715 points in a row within 1σ, either sideStratification: limits too wide or mixed streams
88 points in a row beyond 1σ, either sideA mixture of two distributions