Home › Resources › EWMA and CUSUM charts

EWMA and CUSUM charts

Charts that remember the past to catch small, sustained shifts much faster than Shewhart charts.

A Shewhart chart judges each point on its own, so it is slow to notice a shift of about 1 sigma or less. EWMA and CUSUM charts accumulate information over time.

EWMA (exponentially weighted moving average)

Each plotted value is a weighted average of the newest reading and the previous EWMA value.

Smaller λ (0.05 to 0.2) gives more memory and catches smaller shifts. A common choice is λ = 0.2 with L ≈ 3 (L = 2.86 gives the same in-control ARL as a 3-sigma chart). EWMA is also robust to non-normal individual data.

CUSUM (cumulative sum)

Keeps running sums of deviations above and below the target, reset at zero.

A signal occurs when either sum exceeds H. Typical settings: K = (half the shift you want to detect) and H = or . The point where the sum started rising estimates when the shift began.

Average run length (ARL)

  • ARL₀: average number of points before a false alarm in a stable process (about 370 for a 3-sigma Shewhart chart).
  • ARL₁: average number of points to detect a real shift. For a 1-sigma shift, a Shewhart individuals chart needs about 44 points; a CUSUM with K = 0.5, H = 5 needs about 10.

Questions and answers

Should I replace my Xbar chart with EWMA?

Use EWMA or CUSUM where small, lasting shifts matter (chemical processes, precision machining). Keep a Shewhart chart, or Shewhart-style limits, to catch large sudden changes quickly.

In RS-1: SPC > EWMA / CUSUM.