Resources What's New Support Download Contact Sales: Arthur-Industrial@outlook.com
Home › Resources › Variables control charts: I-MR, Xbar-R, Xbar-S

Variables control charts: I-MR, Xbar-R, Xbar-S

Formulas, constants, when to use each, and a worked example.

I-MR (individuals and moving range)

Plots each reading and the moving range (difference between consecutive readings).

with for moving ranges of two. Individuals charts are more sensitive to non-normal data than Xbar charts.

Xbar-R

Plots subgroup averages and ranges.

For : , , .

Xbar-S

Uses subgroup standard deviations instead of ranges; more efficient for .

Worked example

25 subgroups of 5 shaft diameters: mm, mm.

  • Xbar limits: = 24.9962 to 25.0078 mm.
  • R chart: mm, .
  • Within sigma: mm.

Reading the pair

Check the R (or S, MR) chart first. Unstable spread makes the Xbar limits meaningless. Then check the Xbar chart for shifts and trends.

Questions and answers

Why are my Xbar limits so much narrower than my tolerance?

The Xbar chart plots averages of 5, which vary times less than single parts. That is expected and is why spec limits must never be drawn on an Xbar chart.

Can subgroups have different sizes?

Yes, especially on Xbar-S charts. The limits then vary with each subgroup's size.

In RS-1: SPC > I-MR, Xbar-R, Xbar-S.